MIL-DTL-5624V
*Even though the presence or absence does not change these limits, samples submitted for
specification conformance testing shall contain the same additives present in the refinery
batch. Regardless of which minimum the refiner elects to meet, the refiner shall report the
MSEP rating on a laboratory hand blend of the fuel with all additives required by the
specification.
15/
For refractometers with dual scales, the DiEGME scale shall be used.
16/
The conductivity shall be in the range of 150 to 600 pS/m at ambient fuel temperature or
29.4° C, whichever is lower.
17/
To assist in the data collection process, the results should be reported to NAVAIR 4.4.5.1,
ryan.turgeon@navy.mil, or NAVAIRSYSCOM, AIR 4.4.5.1, BLDG 2360, PSEF, 22229
Elmer Road, Patuxent River, MD 20670-1534.
3.5 Additional requirements for finished fuels containing synthesized hydrocarbons (JP-5
only). Finished fuels containing synthesized hydrocarbons shall meet the additional
requirements specified in Table IV, when tested in accordance with the specified test methods.
TABLE IV. Additional requirements of JP-5 containing synthesized hydrocarbons.
Property
JP-5
ASTM Test Method
Aromatics, vol %, min
8.0
D1319
D861/ or D28872/
Distillation
T50-T10, ° C, min
15
T90-T10, ° C, min
40
Lubricity, mm, max
0.85
D5001
1/
Referee Test Method
2/
ASTM D2887 results shall be converted to estimated ASTM D86 results by application of
the correlation in Appendix X4 of ASTM D2887 for comparison with the specified property
criteria.
3.6 Workmanship. At the time of Government acceptance, the finished fuel shall be clear
and bright and visually free from undissolved water, sediment, or suspended matter. In case of
dispute, the fuel shall be clear and bright at 21° C and shall contain no more than 1.0 mg/L of
particulate matter.
4. VERIFICATION
4.1 Conformance inspection. Conformance inspection shall consist of all examinations,
inspections and tests of this specification.
4.1.1 Inspection lot. For conformance inspection, individual lots shall be examined,
inspected, and tested as specified herein to ensure individual lots meet all the requirements
specified in section 3.